skip to main content

ANALISIS KEGAGALAN CONNECTING ROD PADA SEPEDA MOTOR 4 LANGKAH DENGAN KAPASITAS 110 CC

*Insannul Fikri  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia
Sri Nugroho  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia
Mohammad Tauviqirrahman  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia

Citation Format:
Abstract

Penelitian ini bertujuan untuk menganalisis mekanisme terjadinya kegagalan connecting rod pada sepeda motor 4 langkah dengan kapasitas 110 cc yang mengalami deformasi plastis pada bagian leher connecting rod. Metode analisis yang dilakukan yaitu pengamatan visual, pengujian komposisi kimia, pengujian metalografi, pengujian kekerasan, dan simulasi numerik. Hasil pengujian komposisi kimia menunjukkan bahwa material connecting rod termasuk dalam kategori baja SAE-AISI 4140. Struktur mikronya memiliki fasa martensit yang didapatkan dari hasil pengujian metalografi. Hasil pengujian kekerasan dengan metode Vickers menunjukkan bahwa rata-rata nilai kekerasan material connecting rod sebesar 500 HV. Dari analisis tegangan (von Mises) dan analisis mode tekuk (eigenvalue buckling) menunjukkan kemiripan mode kagagalan tekuk yang terjadi dimana beban yang diterima connecting rod melebihi pembebanan normal dan terjadi di daerah titik tegangan maksimumnya. Hasil ini juga diperkuat dengan riwayat pemakaian sepeda motor yang telah dimodifikasi dengan menaikkan kompresi untuk mendapatkan kecepatan yang diinginkan tanpa mempertimbangkan kekuatan dari komponen connecting rod.

Fulltext View|Download
Keywords: analisis kegagalan; connecting rod; kegagalan tekuk; sae-aisi 4140
  1. Godara, S. S., Brenia, V., Soni, A. K., Shekhawat, R. S., & Saxena, K. K., 2022. Design & Analysis of Connecting Rod Using Ansys Software. Materials Today: Proceedings, 56, pp.1896-1903
  2. Pani, A. R., Patel, R. K., & Ghosh, G. K., 2020. Buckling Analysis and Material Selection of Connecting Rod to Avoid Hydro-Lock Failure. Materials Today: Proceedings, 27, pp.2121-2126
  3. Chao, J., 2019. Fretting-Fatigue Induced Failure of a Connecting Rod. Engineering Failure Analysis, 96, pp.186-201
  4. Witek, L., & Zelek, P., 2019. Stress and Failure Analysis of the Connecting Rod of Diesel Engine. Engineering Failure Analysis, 97, pp.374-382
  5. Rezvani, M. A., Javanmardi, D., & Mostaghim, P., 2018. Diagnosis of EMD645 Diesel Engine Connecting Rod Failure Through Modal Testing and Finite element Modeling. Engineering Failure Analysis, 92, pp.50-60
  6. Lee, M. K., Lee, H., Lee, T. S., & Jang, H., 2010. Buckling Sensitivity of a Connecting Rod to the Shank Sectional Area Reduction. Materials and Design, 31, pp.2796-2803
  7. Bari, K., Rolfe, A., Christofi, A., Mazzuca, C., & Sudhakar, K. V., 2017. Forensic Investigation of a Failed Connecting Rod from a Motorcycle Engine. Case Studies in Engineering Failure Analysis, 9, pp.9-16
  8. American Society for Metals, 1990. ASM Handbook Vol.1, Properties and Selection: Irons, Steels, and High-Performance Alloys. Vol.1, ASM Handbook, ASM International, pp.1-2521
  9. American Society for Metals, 1985. ASM Handbook Vol.9, Metallography and Microstructures. Vol.9, ASM Handbook, ASM International, pp.1-1627
  10. American Society for Metals, 1991. ASM Handbook Vol.4, Heat Treating. Vol.4, ASM Handbook, ASM International, pp.1-2173
  11. Rakic, S., Bugaric, U., Radisavljevic, I., & Bulatovic, Z., 2017. Failure Analysis of a Special Vehicle Engine Connecting Rod. Engineering Failure Analysis, 79, pp.98-109