Abstract

The industry of recoloring jeans used pigment in the process of fabrication produces liquid waste containing Fe that  was 23.90 mg/l, Mn is 35.18 mg/l that exceeded the threshold according to Central Java Provincial Regulation No. 5 of 2012 about Waste Water Quality Standard for Fe that was 5 mg/l and Mn was 2 mg/l. Waste water that was not in accordance with the quality standard can cause environmental damage and health. The usage of calcium oxide with coagulation-flocculation method is one of the technologies used to decrease the liquid waste metal content. The purpose of this research was to know the use of calcium oxide to decrease metal content of Fe and Mn toward liquid waste recoloring jeans at Magelang district. The type of this research was  true experimental of pretest and posttest with control group design. Sample of this research wasted water of recoloring jeans at Magelang district. Data analysis with Shapiro Wilk test (p≤ 0.05). The result shown early content of Fe was 0.805 mg/l and the content of Mn was 4.188 mg/l. The average pH and temperature of liquid waste before treatment was 11 and 28.02°C. After treatment the pH and temperature of calcium oxide 4 gr was 11 and 28.47°C then it was 11 and 28.44°C for calcium oxide 5 gr. There was decreasing metal content with distributing calcium oxide 4 gr as 13.7% for Fe and 27% of Mn, meanwhile the decreasing for calcium oxide  5 gr was 30.7% for Fe and 28.2% for Mn. Shapiro Wilk test shown 0.0001 (p≤0.05) which means there was a different decrease of metal content of Fe recoloring jeans with various dose treatment of calcium oxide. Instead  for metal content of Mn that shown 0.171 (p≥0.05) which means there was no difference decrease of metal content of Mn recoloring jeans with various dose treatment of calcium oxide.

Fulltext View|Download
Keywords: Liquid waste, recoloring jeans, calcium oxide, Fe, Mn

Article Metrics:

Article Info
Section: Kesehatan Lingkungan
Recent articles
ANALISIS PENYEBAB RENDAHNYA KINERJA ORGANISASI DI PUSKESMAS CANDILAMA KOTA SEMARANG ANALISIS MOTIVASI KERJA PERAWAT DI RSUD AMBARAWA KABUPATEN SEMARANG TAHUN 2017 HUBUNGAN PERSEPSI LINGKUNGAN TEMPAT TINGGAL DAN PEMANFAATAN SMARTPHONE DENGAN PERILAKU BERPACARAN YANG BERISIKO PADA REMAJA YANG TINGGAL DI DAERAH LOKALISASI GAMBILANGU KOTA SEMARANG HUBUNGAN PERSEPSI EFEK SAMPING IUD, DUKUNGAN SUAMI DAN KEPRAKTISAN IUD DENGAN KEIKUTSERTAAN AKSEPTOR IUD DI KELURAHAN JATISARI KECAMATAN MIJEN KOTA SEMARANG TAHUN 2016 GAMBARAN TINGKAT KECEMASAN DAN DERAJAT SERANGAN ASMA PADA PENDERITA DEWASA ASMA BRONKIAL (Studi di WilayahKerja Puskesmas Gunungpati, Kota Semarang Tahun 2016) HUBUNGAN PENGETAHUAN, DUKUNGAN KELUARGA SERTA PERILAKU PENDERITA DIABETES MELITUS TIPE 2 TERHADAP KEJADIAN ULKUS KAKI DIABETES (Studi di Wilayah Kerja Puskesmas Ngesrep Semarang) PENGARUH PEMBERIAN PENDIDIKAN MANAJEMEN LAKTASI TERHADAP PERILAKU KETUA DASAWISMA DALAM PENDAMPINGAN IBU MENYUSUI DI KELURAHAN PEDURUNGAN KIDUL KOTA SEMARANG TAHUN 2017 PERBEDAAN POLA KONSUMSI REMAJA PUTERI OVERWEIGHT DAN NORMAL DI SMA NEGERI 1 SIBORONGBORONG KOTA MEDAN TAHUN 2017 ANALISIS FAKTOR-FAKTOR YANG BERHUBUNGAN DENGAN KESADARAN PELAPORAN KECELAKAAN KERJA PADA PEKERJA KONSTRUKSI PROYEK PEMBANGUNAN GEDUNG FAKTOR-FAKTOR YANG BERHUBUNGAN DENGAN STRES KERJA PADA ANGGOTA POLISI SATUAN LALU LINTAS POLRES METRO BEKASI KOTA EFEKTIVITAS PENURUNAN KADAR AMONIAK DAN KADAR FOSFAT DI INSTALASI PENGOLAHAN AIR LIMBAH RSUD SUNAN KALIJAGA DEMAK HUBUNGAN RIWAYAT PAJANAN PESTISIDA DENGAN KEJADIAN DIABETES MELITUS TIPE 2 PADA PETANI PENYEMPROT DI KECAMATAN NGABLAK KABUPATEN MAGELANG PERILAKU SEKSUAL PRANIKAH PADA MAHASISWA KOST (STUDI KASUS PADA PERGURUAN TINGGI “X” DI WILAYAH JAKARTA BARAT) FAKTOR-FAKTO YANG BERHUBUNGAN DENGAN TINGKAT KEPATUHAN PERAWAT TERHADAP PENGGUNAAN ALAT PELINDUNG DIRI (APD) DI RSUP DR. KARIADI SEMARANG (Studi Kasus di Instalasi Rawat Inap Merak) More recent articles

Last update:

No citation recorded.

Last update:

No citation recorded.