Abstract
Nowadays multistorey building are widely spread in almost every city in Indonesia, especially in metropolitan city such as Jakarta. The overuse of electricity in multistorey building has unconsciously remained hazardous potential to trigger fire. One of the prevention act to the fire spreading is by installing the proper hydrant system around the building. In this writings, evaluation regarding to the hydrant building installation refers to a government regulation. PT. Pertamina Lubricants office building is used for office activities and laboratorial test, where the overuse of electricity could trigger another hazardous potential which is chemical hazards that could cause fire. PT. Pertamina Lubricants building has already had hydrant installation with the quantity of 5 hydrant box. The placement and the number of the hydrant box in every stairs hasn’t reached the standard. The evaluation result on the hydrant system of the building and the component completeness has attained the standard with the precentage of 68.2% allowed. Any broken hydrant tools or components are not found in this building, every hydrant parts is in a good condition.
Fulltext View|Download
Keywords: Active Fire Protection, Hydrant System Installation

Article Metrics:

Article Info
Section: Keselamatan dan Kesehatan Kerja
Recent articles
ANALISIS KUALITAS PELAYANAN REHABILITASI SESUAI STANDAR PELAYANAN BAGI PENYALAH GUNA NAPZA DI RUMAH DAMAI, GUNUNGPATI, SEMARANG Analisis Hubungan Gaya Kepemimpinan dan Motivasi dengan Kinerja Pegawai RumahSakit Bhayangkara Tk. I Raden Said Sukanto Jakarta HUBUNGAN PENGETAHUAN DAN SIKAP WANITA PUS DENGAN KEJADIAN PERNIKAHAN DINI DI DESA LANJAN KECAMATAN SUMOWONO KABUPATEN SEMARANG TAHUN 2013 PENGARUH MOTIVASI DAN PERSEPSI PELAYANAN TERHADAP KETERATURAN ANTENATAL CARE PADA IBU HAMIL DI PUSKESMAS NGEMPLAK SIMONGAN KOTA SEMARANG PADA TRI WULAN I TAHUN 2015 Hubungan Faktor Host (Umur 6 Bulan-14 Tahun) Dan Keberadaan Vektor Dengan Kejadian Demam Berdarah Dengue di Wilayah Kerja Puskesmas Kedungmundu Semarang Relationship Of Host Factors (Ages 6 Months - 14 Years) And Existence Vector With Dengue Hemorrhagic PENGARUH VARIASI WARNA KUNING PADA FLY GRILL TERHADAP KEPADATAN LALAT (STUDI DI TEMPAT PELELANGAN IKAN TAMBAK LOROK KOTA SEMARANG) Effect Of Variation The Color Yellow On Fly Grill To Density Of Flies (Study At Fish Ouction Place Tambak Lorok Semarang Cit HUBUNGAN ASUPAN SERAT, LEMAK, DAN POSISI BUANG AIR BESAR DENGAN KEJADIAN KONSTIPASI PADA LANSI GAMBARAN PEMANFAATAN BILIK LAKTASI DI SARANA UMUM KOTA SEMARANG TAHUN 2015 ANALISIS FAKTOR-FAKTOR YANG MEMPENGARUHI KEBIASAAN MENGEMUDI TIDAK AMAN PADA SOPIR ANGKOT DAERAH TEMBALANG KOTA SEMARANG ANALISIS HUBUNGAN ANTARA PENGETAHUAN DENGAN APLIKASI TANGGAP DARURAT KEBAKARAN PADA PERAWAT DI INSTALASI RAWAT INAP RSUD PASAR REBO, JAKARTA TIMUR PERBEDAAN KADAR TIMBAL (Pb) DALAM DARAH BERDASARKAN JENIS PEKERJAAN PADA PEKERJA INDUSTRI PENGECORAN LOGAM DI CV. BONJOR JAYA, CEPER, KLATEN Pengaruh Variasi Lama Waktu Kontak Dan Diameter Media Karang Jahe (Acropora Sp.) Terhadap Penurunan Kadar Logam Chromium (Cr) Limbah Cair Batik Home IndustryKota Pekalongan Analisis Faktor – Faktor yang Mempengaruhi Remaja Putri terhadap Perilaku Kekerasan dalam Pacaran di SMA “X” Kota Semarang Faktor-faktor yang Berhubungan dengan Perilaku Penyalahgunaan Narkoba pada Remaja Usia 15-19 Tahun Di Kecamatan Semarang Utara Kota Semarang More recent articles

Last update:

No citation recorded.

Last update:

No citation recorded.