EVALUASI INSTALASI SISTEM HIDRAN PADA GEDUNG KANTOR PT. PERTAMINA LUBRICANTS JAKARTA UTARA

*Lanti Annistyaningrum  -  , Indonesia
Ekawati Ekawati  -  , Indonesia
Bina Kurniawan  -  , Indonesia
Received: 30 Jun 2016; Published: 13 Dec 2017.

Citation Format:
Abstract
Nowadays multistorey building are widely spread in almost every city in Indonesia, especially in metropolitan city such as Jakarta. The overuse of electricity in multistorey building has unconsciously remained hazardous potential to trigger fire. One of the prevention act to the fire spreading is by installing the proper hydrant system around the building. In this writings, evaluation regarding to the hydrant building installation refers to a government regulation. PT. Pertamina Lubricants office building is used for office activities and laboratorial test, where the overuse of electricity could trigger another hazardous potential which is chemical hazards that could cause fire. PT. Pertamina Lubricants building has already had hydrant installation with the quantity of 5 hydrant box. The placement and the number of the hydrant box in every stairs hasn’t reached the standard. The evaluation result on the hydrant system of the building and the component completeness has attained the standard with the precentage of 68.2% allowed. Any broken hydrant tools or components are not found in this building, every hydrant parts is in a good condition.
Fulltext View|Download
Keywords: Active Fire Protection, Hydrant System Installation

Article Metrics:

Article Info
Section: Keselamatan dan Kesehatan Kerja
Recent articles
IMPLEMENTASI FUNGSI POKOK PELAYANAN PRIMER PUSKESMAS SEBAGAI GATEKEEPER DALAM PROGRAM JKN (STUDI DI PUSKESMAS JUWANA KABUPATEN PATI) ANALISIS KUALITAS PELAYANAN REHABILITASI SESUAI STANDAR PELAYANAN BAGI PENYALAH GUNA NAPZA DI RUMAH DAMAI, GUNUNGPATI, SEMARANG PENGARUH MOTIVASI DAN PERSEPSI PELAYANAN TERHADAP KETERATURAN ANTENATAL CARE PADA IBU HAMIL DI PUSKESMAS NGEMPLAK SIMONGAN KOTA SEMARANG PADA TRI WULAN I TAHUN 2015 HUBUNGAN AKTIVITAS FISIK DENGAN GANGGUAN MENSTRUASI WANITA PASANGAN USIA SUBUR DI DESA TEMANGGUNG KECAMATAN KALIANGKRIK KABUPATEN MAGELANG TAHUN 2015 UJI RESISTENSI INSEKTISIDA MALATHION 0,8% TERHADAP NYAMUK Aedes aegypti DI WILAYAH FOGGING KANTOR KESEHATAN PELABUHAN KELAS II AMBON BEBERAPA FAKTOR RISIKO KEJADIAN HIPERTIROID PADA WANITA USIA SUBUR DI KABUPATEN MAGELANG “Studi Kasus di Klinik Litbang BP2GAKI Magelang” HUBUNGAN PRAKTIK PEMBERIAN AIR SUSU IBU (ASI) DENGAN STATUS GIZI BAYI (USIA 0-6 BULAN) DI WILAYAH KERJA PUSKESMAS GAYAMSARI KOTA SEMARANG HUBUNGAN ASUPAN SERAT, LEMAK, DAN POSISI BUANG AIR BESAR DENGAN KEJADIAN KONSTIPASI PADA LANSI ANALISIS FAKTOR-FAKTOR YANG MEMPENGARUHI KECELAKAAN KERJA PADA PEKERJA MAINTENANCE ELEKTRIKAL DALAM MENERAPKAN WORK PERMIT DI PT. X SEMARANG ANALISIS SISTEM PENCAHAYAAN DI RUANG SIPIL/SARANA DENGAN SNI NOMOR 03-6575-2001 TENTANG PERANCANGAN SISTEM PENCAHAYAAN BUATAN PT X GRESIK ANALISIS HUBUNGAN DAN SANITASI DENGAN KEBERADAAN COLIFORM FECAL PADA HANDLE PINTU TOILET DI TEMPAT – TEMPAT UMUM DI KOTA SEMARANG KEMAMPUAN TAWAS DAN SERBUK BIJI ASAM JAWA (Tamarindusindica) UNTUK MENURUNKAN KADAR COD (Chemical Oxygen Demand) PADA LIMBAH CAIR LAUNDRY Faktor – Faktor yang Berhubungan dengan Perilaku Seks Berisiko HIV/AIDS pada Tenaga Kerja Bongkar Muat (TKBM) di Pelabuhan Tanjung Emas Semarang Analisis Faktor-Faktor Penyebab Perilaku Merokok Remaja di SMK “X” Surakarta More recent articles

Last update:

No citation recorded.

Last update:

No citation recorded.