Nowadays multistorey building are widely spread in almost every city in Indonesia, especially in metropolitan city such as Jakarta. The overuse of electricity in multistorey building has unconsciously remained hazardous potential to trigger fire. One of the prevention act to the fire spreading is by installing the proper hydrant system around the building. In this writings, evaluation regarding to the hydrant building installation refers to a government regulation. PT. Pertamina Lubricants office building is used for office activities and laboratorial test, where the overuse of electricity could trigger another hazardous potential which is chemical hazards that could cause fire. PT. Pertamina Lubricants building has already had hydrant installation with the quantity of 5 hydrant box. The placement and the number of the hydrant box in every stairs hasn’t reached the standard. The evaluation result on the hydrant system of the building and the component completeness has attained the standard with the precentage of 68.2% allowed. Any broken hydrant tools or components are not found in this building, every hydrant parts is in a good condition.
Fulltext View|Download
Keywords: Active Fire Protection, Hydrant System Installation

Article Metrics:

Article Info
Section: Keselamatan dan Kesehatan Kerja
Recent articles
ANALISIS FAKTOR INTERNAL DAN EKSTERNAL SEBAGAI BAHAN PENYUSUN STRATEGI PENCEGAHAN FRAUD DANA KAPITASI PUSKESMAS DI KOTA SEMARANG IMPLEMENTASI FUNGSI POKOK PELAYANAN PRIMER PUSKESMAS SEBAGAI GATEKEEPER DALAM PROGRAM JKN (STUDI DI PUSKESMAS JUWANA KABUPATEN PATI) HUBUNGAN BEBERAPA FAKTOR DENGAN PERILAKU SEKSUAL BERISIKO IMS PADA WARIA BINAAN PONDOK PESANTREN (PONPES) WARIA SENIN- KAMIS YOGYAKARTA TAHUN 2015 HUBUNGAN AKTIVITAS FISIK DENGAN GANGGUAN MENSTRUASI WANITA PASANGAN USIA SUBUR DI DESA TEMANGGUNG KECAMATAN KALIANGKRIK KABUPATEN MAGELANG TAHUN 2015 UJI RESISTENSI INSEKTISIDA MALATHION 0,8% TERHADAP NYAMUK Aedes aegypti DI WILAYAH FOGGING KANTOR KESEHATAN PELABUHAN KELAS II AMBON SURVEI KEBERADAAN FORMALIN PADA PRODUK PERIKANAN LAUT SEGAR YANG DIJUAL DI PASAR TRADISIONAL KOTA SEMARANG Survey of Formaldehyde Existence In Fresh Sea Fisheries Product Sold At Traditional Market Of Semarang City GAMBARAN PEMANFAATAN BILIK LAKTASI DI SARANA UMUM KOTA SEMARANG TAHUN 2015 HUBUNGAN ASUPAN SERAT, LEMAK, DAN POSISI BUANG AIR BESAR DENGAN KEJADIAN KONSTIPASI PADA LANSI FAKTOR-FAKTOR YANG BERHUBUNGAN TERHADAP PERILAKU SAFETY RIDING PADA MAHASISWA FAKULTAS X UNIVERSITAS DIPONEGORO Analisis Implementasi Contractor Safety Management System (CSMS) Terhadap Pekerjaan Berisiko Tinggi di PT Pertamina (Persero) Refinery Unit IV Cilacap PERBEDAAN KADAR TIMBAL (Pb) DALAM DARAH BERDASARKAN JENIS PEKERJAAN PADA PEKERJA INDUSTRI PENGECORAN LOGAM DI CV. BONJOR JAYA, CEPER, KLATEN PENGARUH VARIASI KONSENTRASI AIR JERUK NIPIS (Citrus aurantifolia) DALAM MENURUNKAN KADAR KADMIUM (Cd) PADA DAGING KERANG DARAH (Anadara granosa) Analisis Faktor – Faktor yang Mempengaruhi Remaja Putri terhadap Perilaku Kekerasan dalam Pacaran di SMA “X” Kota Semarang Faktor-Faktor Yang Berhubungan Dengan Perilaku Kerja Karyawan Penderita Aging Disease Di PT Holcim Indonesia Tbk Cilacap Plant More recent articles

Last update:

No citation recorded.

Last update:

No citation recorded.