skip to main content

ANALISA EKSERGI PADA PEMBANGKIT LISTRIK TENAGA UAP XYZ KAPASITAS 1070 MW MENGGUNAKAN PEMODELAN CYCLE TEMPO

*Putro Adi Nugroho  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia
Berkah Fajar TK  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia
Eflita Yohana  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia

Citation Format:
Abstract
Peningkatan performa PLTU merupakan salah satu cara untuk meningkatkan efisiensi, mengurangi dampak kerusakan lingkungan, mengurangi konsumsi bahan bakar sehingga PLTU bekerja dengan kondisi lebih baik dan mendapatkan keuntungan lebih baik. PLTU yang beroperasi pada performa yang buruk hanya akan menyebabkan kerugian dan berpotensi merusak lingkungan karena emisinya lebih buruk, dan konsumsi bahan bakarnya lebih banyak.  Tujuan dari penelitian ini adalah untuk mengetahui nilai efisiensi eksergi dan energi pada PLTU XYZ  yang memiliki kapasitas produksi sebesar 1070 MW. Dengan mengetahui data efisiensi pembangkit ini, maka performa pembangkit dapat diidentifikasi dan dapat dilakukan peningkatan performa berdasarkan data efisiensi yang diperoleh. Software yang digunakan dalam penelitian ini adalah software Cycle-Tempo. Analisa dilakukan pada tiga kondisi variasi beban yaitu beban 50%, 75% dan 100%. Dari hasil penelitian ini, didapatkan nilai efisiensi pembangkit pada kondisi 50% sebesar 38.76%, kondisi 75% sebesar 40,75% dan kondisi 100% sebesar 41,82%. Destruksi eksergi terbesar terjadi  pada boiler dan reheater untuk kondisi 50% sebesar 661.18 MW dengan persentase destruksi eksergi 51.33%, kondisi 75% sebesar 938.28 MW dengan persentase destruksi eksergi 50.07% dan kondisi 100% sebesar 1214.59 MW dengan persentase destruksi eksergi 49.35%. Nilai destruksi eksergi terkecil pada CEP pada kondisi 50% sebesar 1.44 MW dengan persentase destruksi eksergi 0.11%, kondisi 75% sebesar 1.46 MW dengan persentase destruksi eksergi 0.08% dan kondisi 100% sebesar 1.48 MW dengan persentase destruksi eksergi 0.06%. Nilai energi losses terbesar pada komponen boiler kondisi 50% sebesar 935.68 MW, kondisi 75% sebesar 1340.6 MW dan kondisi 100% sebesar 1738.9 MW.
Fulltext View|Download
Keywords: cycle tempo; destruksi eksergi; eksergi; energi; energy losses; pltu
  1. O. J. Khaleel, F. Basim Ismail, T. Khalil Ibrahim, and S. H. bin Abu Hassan, “Energy and exergy analysis of the steam power plants: A comprehensive review on the Classification, Development, Improvements, and configurations,” Ain Shams Engineering Journal, vol. 13, no. 3, p. 101640, May 2022, doi: 10.1016/J.ASEJ.2021.11.009
  2. I. H. Aljundi, “Energy and exergy analysis of a steam power plant in Jordan,” Appl Therm Eng, vol. 29, no. 2–3, pp. 324–328, Feb. 2009, doi: 10.1016/J.APPLTHERMALENG.2008.02.029
  3. P. R. Kumar, V. R. Raju, and N. R. Kumar, “Simulation and parametric optimisation of thermal power plant cycles,” Perspect Sci (Neth), vol. 8, pp. 304–306, Sep. 2016, doi: 10.1016/J.PISC.2016.04.060
  4. B. Rudiyanto et al., “Energy and Exergy Analysis of Steam Power Plant in Paiton, Indonesia,” in IOP Conference Series: Earth and Environmental Science, Institute of Physics Publishing, Jul. 2019. doi: 10.1088/1755-1315/268/1/012091
  5. M. Kamil Mohammed, W. Hussein Al Doori, A. Hussain Jassim, T. Khalil Ibrahim, and A. Tawfeeq Al-Sammarraie, “Energy and Exergy Analysis of the Steam Power Plant Based On Effect the Numbers of Feed Water Heater,” Journal of Advanced Research in Fluid Mechanics and Thermal Sciences Journal homepage, vol. 56, pp. 211–222, 2019, [Online]. Available: www.akademiabaru.com/arfmts.html
  6. V. R. et al. , Vishnu Rajeev et al., “Energy and Exergy Analysis of a 3500 MW Coal Fired Thermal Power Plant using Cycle-Tempo,” International Journal of Mechanical and Production Engineering Research and Development, vol. 10, no. 3, pp. 3861–3870, 2020, doi: 10.24247/ijmperdjun2020368
  7. R. Pachaiyappan and J. Dasa Prakash, “Improving the Boiler Efficiency by Optimizing the Combustion Air,” Applied Mechanics and Materials, vol. 787, pp. 238–242, Aug. 2015, doi: 10.4028/www.scientific.net/amm.787.238
  8. A. S. Karakurt and Ü. Güneş, “Performance analysis of a steam turbine power plant at part load conditions,” Journal of Thermal Engineering, vol. 3, no. 2, pp. 1121–1128, Apr. 2017, doi: 10.18186/thermal.298611
  9. H. S. B. M. D. D. MJ Moran, Introduction to thermal systems engineering: thermodynamics, fluid mechanics, and heat transfer. John Wiley, 2002
  10. N. Hasananto, D. B. Darmadi, and L. Yuliati, “Modelling of load variation effect on the steam power plant heat rate and performance using Gatecycle,” IOP Conf Ser Mater Sci Eng, vol. 1034, no. 1, p. 012048, Feb. 2021, doi: 10.1088/1757-899x/1034/1/012048