skip to main content

Perbedaan Efektivitas Variasi Konsentrasi Feri Klorida DAN Polyalumunium Chloride dalam Menurunkan Kadar Chemical Oxygen Demand (COD) pada Air Lindi TPA Jatibarang Kota Semarang

*Kartika Permatasari  -  , Indonesia
Onny Setiani  -  , Indonesia
Mursid Raharjo  -  , Indonesia
Published: 2 Mar 2016.

Citation Format:
Abstract

Volume of solid waste increases every year. The amount is equal with the increase of volume of leachate in landfill. The result of  earlier COD examination is 5011,34 mg/l. The number surpasses the standard which is stated in the minister of environment regulation number 5 years 2014 for water type II which is  300 mg/l. The high level of leachate COD  causes eutrophication and impairment of water use. The research aims to tell the difference between the effectiveness of PAC and Ferry Chloride  in lowering COD level of TPA Jatibarang Semarang leachate using concentration variations. The kind of research is by experimenting with pretest-posttest design .The sample is taken from leachate in landfill. The method of sample examination uses covered reflux spectrophotometrically and the analysis of data uses both Kruskall-Wallis test and Mann-Whitney test. The average of the results in examining COD is 4858,5 mg/l. The percentages of  the  decline in COD level by using PAC concentration variations which are 4%, 8%, and 12% successively are 3.9%, 6.9% and 6.7%. Meanwhile, by adding Ferry Chloride with the same concentrations, successively decrease the COD levels into 9.21%, 36.62%, and 36.74%. The result of Kruskall-Wallis test shows that there are differences in the decline percentages of COD level after treatment using PAC and Ferry Chloride (p-value 0.040 and 0.041). The result of Mann-Whitney test shows that the differences in the decrease of COD level of leachate is significant (p-value=0.05). However, the concentration of 12% Ferry Chloride is the concentration that lowers the greatest COD level,although it hasn’t reached the quality standard yet.

Fulltext View|Download
Keywords: COD, Leachate, PAC, Ferry Chloride

Article Metrics:

Article Info
Section: Kesehatan Lingkungan
Recent articles
PERSEPSI PASIEN RAWAT INAP KLAS III TERHADAP RESPONSIVENESS PELAYANAN DOKTER DAN PERAWAT DI RUMAH SAKIT UMUM DAERAH RAA SOEWONDO PATI GAMBARAN SEKTOR INFORMAL NELAYAN KELURAHAN CILINCING JAKARTA UTARA SEBAGAI CALON PESERTA BPJS KESEHATAN HUBUNGAN REWARD & PUNISHMENT DAN PENGAWASAN KINERJA DENGAN KUALITAS DATA SENSUS HARIAN RAWAT INAP OLEH PERAWAT DI RS MARDI RAHAYU KUDUS HUBUNGAN BEBERAPA FAKTOR DETERMINAN DENGAN KUALITAS DATA ASUHAN KEPERAWATAN DI RUANG RAWAT INAP RUMAH SAKIT UMUM KOTA BEKASI TAHUN 2015 PENGUJIAN DAUN JERUK PURUT (Citrus hystrix) SEBAGAI ZAT PENOLAK ALAMI BAGI KECOA JERMAN (Blatella germanica) DEWASA DI LABORATORIUM Uji Efektifitas Entomophatogenic Fungi Beauveria bassiana Terhadap Kematian Blattella germananica (L) FAKTOR – FAKTOR YANG BERHUBUNGAN dengan USIA MENOPAUSE (Studi di Puskesmas Bangetayu Tahun 2015) PENGETAHUAN, SIKAP, DAN PRAKTIK DALAM PEMBERIAN ASI EKSKLUSIF DI WILAYAH KERJA PUSKESMAS REMBANG 2 DAN PUSKESMAS SARANG ANALISIS MANAJEMEN PELAKSANAAN PADA KESIAPSIAGAAN DAN TANGGAP DARURAT DI GEDUNG PERKANTORAN X FAKTOR RISIKO YANG BERHUBUNGAN DENGAN KAPASITAS VITAL PARU PADA PEKERJA BAGIAN PRODUKSI DI INDUSTRI BATU KAPUR FAKTOR LINGKUNGAN DAN PERILAKU KEJADIAN LEPTOSPIROSIS DI KOTA SEMARANG Perbedaan Efektivitas Variasi Konsentrasi Feri Klorida DAN Polyalumunium Chloride dalam Menurunkan Kadar Chemical Oxygen Demand (COD) pada Air Lindi TPA Jatibarang Kota Semarang PEMANFAATAN POS PEMBINAAN TERPADU PENYAKIT TIDAK MENULAR (POSBINDU PTM) OLEH WANITA LANSIA DALAM RANGKA MENCEGAH PENYAKIT TIDAK MENULAR DI WILAYAH KERJA PUSKESMAS CILONGOK 1 FAKTOR-FAKTOR YANG BERHUBUNGAN DENGAN PERILAKU PENGGUNAAN ALAT KONTRASEPSI PADA WANITA USIA SUBUR DI PUSKESMAS JOMBANG-KOTA TANGERANG SELATAN More recent articles

Last update:

No citation recorded.

Last update:

No citation recorded.