skip to main content

ANALISIS KEANDALAN KOMPONEN KRITIS ELECTRICAL SUBMERSIBLE PUMP MENGGUNAKAN METODE RELIABILITY BLOCK DIAGRAM DAN FAULT TREE ANALYSIS

*Nabiel Nausal Putra  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia
Gunawan Dwi Haryadi  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia
Yusuf Umardani  -  Department of Mechanical Engineering, Universitas Diponegoro, Jl. Prof. Sudarto, SH, Tembalang, Semarang, Indonesia 50275, Indonesia

Citation Format:
Abstract

Electrical Submersible Pump (ESP) merupakan peralatan penting dalam sistem drainase dan pengendalian banjir karena mampu memindahkan fluida berkapasitas besar. Kegagalan komponen ESP dapat menghentikan proses pemompaan dan meningkatkan waktu henti, sehingga diperlukan analisis keandalan untuk menentukan komponen kritis dan prioritas inspeksi. Penelitian ini menggunakan metode Reliability Block Diagram (RBD), Fault Tree Analysis (FTA), Probability of Failure (PoF), Risk Level Justification (RLJ), dan Risk Based Inspection (RBI). Data penelitian terdiri atas 346 catatan harian breakdown dari enam unit ESP dengan total waktu henti 8.304 jam, yang dikelompokkan menjadi sembilan kejadian kegagalan aktual. Hasil analisis menunjukkan bahwa Pump 2 merupakan unit paling kritis dengan waktu henti 2.520 jam (30,35% dari total). Melalui RBD dan FTA, komponen kritis yang teridentifikasi meliputi bearing assembly, shaft/joint shaft, dan impeller, dengan bearing assembly memiliki PoF tertinggi sebesar 0,3960 dan keandalan 0,6040 pada horizon operasi 720 jam. Berdasarkan Risk Level Justification, ketiga komponen tersebut dikategorikan dalam risiko tinggi hingga kritis. Strategi RBI yang direkomendasikan berfokus pada pemantauan kondisi operasi, inspeksi komponen rotating, pengendalian debris, dan penyediaan spare part kritis guna menekan waktu henti dan meningkatkan keandalan operasi ESP.

Keywords: electrical submersible pump; fault tree analysis; keandalan; reliability block diagram; risk based inspection; risk level justification
Article Info
  1. Irawan AR, Umardani Y, Haryadi GD. Analisis keandalan pompa pada sistem perpipaan menggunakan metode Reliability Block Diagram dan Fault Tree Analysis. Jurnal Teknik Mesin. 2026;14(1):119–124
  2. Carnevali L, Ciani L, Fantechi A, Gori G, Papini M. An efficient library for reliability block diagram evaluation. Applied Sciences. 2021;11(9):4026
  3. Fakher S, Khlaifat A, Hossain ME, Nameer H. Rigorous review of electrical submersible pump failure mechanisms and their mitigation measures. Journal of Petroleum Exploration and Production Technology. 2021;11:3799–3814
  4. Chen L, Wei L, Wang Y, Wang J, Li W. Monitoring and predictive maintenance of centrifugal pumps based on smart sensors. Sensors. 2022;22(6):2106
  5. API RP 580. Elements of a risk-based inspection program. 4th ed. American Petroleum Institute; 2023
  6. API RP 581. Risk-based inspection methodology. 4th ed. American Petroleum Institute; 2025
  7. Dai Y, Shi W, Yang Y, Xie Z, Zhang Q. Numerical analysis of unsteady internal flow characteristics in a bidirectional axial flow pump. Sustainability. 2024;16(1):224
  8. Jimenez-Roa LA, Heskes T, Tinga T, Stoelinga MIA. Automatic inference of fault tree models via multi-objective evolutionary algorithms. IEEE Transactions on Dependable and Secure Computing. 2023;20(4):3317–3327
  9. Niloofar P, Lazarova-Molnar S. Collaborative data-driven reliability analysis of multi-state fault trees. Proceedings of the Institution of Mechanical Engineers, Part O: Journal of Risk and Reliability. 2023;237(5):886–896
  10. Liu T, Pan Z, Song G. System reliability evaluation and dynamic optimization based on an improved reliability block diagram. Proceedings of the Institution of Mechanical Engineers, Part O: Journal of Risk and Reliability. 2024;238(4):704–717