BibTex Citation Data :
@article{JKM38035, author = {Maulia Fajriati and Muslikha Nourma Rhomadhoni}, title = {EVALUASI KECUKUPAN BANGUNAN PADA AREA PERKANTORAN}, journal = {Jurnal Kesehatan Masyarakat}, volume = {12}, number = {1}, year = {2024}, keywords = {Building sufficiency; ERP}, abstract = { Fire is one of the impacts of potential hazards that often occur in the work area. Every company needs to have an automatic fire prevention and control system that meets fire prevention and control requirements, one of which is the administration of the placement of the number of workers that does not exceed the existing standard limits/rules. This type of research is a case study research that uses quantitative methods using secondary data, the data needed is data on the number of workers and building area in each work area. The results of the study show that the actual number of workers in each work area when compared to the number of people according to the standard, it can be said that they have met the standards that should be except for the 2nd floor of the Foundry office building. Researchers suggest companies to make improvements to all work area buildings to has an emergency response system that meets the requirements of integrated fire prevention and control and does not violate national and international standards . }, issn = {2356-3346}, pages = {8--11} doi = {10.14710/jkm.v12i1.38035}, url = {https://ejournal3.undip.ac.id/index.php/jkm/article/view/38035} }
Refworks Citation Data :
Fire is one of the impacts of potential hazards that often occur in the work area. Every company needs to have an automatic fire prevention and control system that meets fire prevention and control requirements, one of which is the administration of the placement of the number of workers that does not exceed the existing standard limits/rules. This type of research is a case study research that uses quantitative methods using secondary data, the data needed is data on the number of workers and building area in each work area. The results of the study show that the actual number of workers in each work area when compared to the number of people according to the standard, it can be said that they have met the standards that should be except for the 2nd floor of the Foundry office building. Researchers suggest companies to make improvements to all work area buildings to has an emergency response system that meets the requirements of integrated fire prevention and control and does not violate national and international standards.
Article Metrics:
Last update:
The Authors submitting a manuscript do so on the understanding that if accepted for publication, copyright of the article shall be assigned to Jurnal Kesehatan Masyarakat (JKM, p-ISSN: 2715-5617, e-ISSN:2356-3346) and Faculty of Public Health, Diponegoro University as the publisher of the journal. Copyright encompasses the rights to reproduce and deliver the article in all form and media, including reprints, photographs, microfilms, and any other similar reproductions, as well as translations.
JKM journal and Faculty of Public Health, Diponegoro University, the Editors and the Advisory Editorial Board make every effort to ensure that no wrong or misleading data, opinions or statements be published in the journal. In any way, the contents of the articles and advertisements published in the JKM journal are the sole and exclusive responsibility of their respective authors and advertisers.
The Copyright Transfer Form can be downloaded here: [Copyright Transfer Form JKM journal]The copyright form should be signed originally and send to the Editorial Office in the form of original mail or scanned document to jkm@live.undip.ac.id.
Jurnal Kesehatan Masyarakat (e-ISSN: 2356-3346, p-ISSN: 2715-5617) is published by Faculty of Public Health, Universitas Diponegoro, Indonesia, under Creative Commons Attribution-ShareAlike 4.0 International License.
View My Stats